Karyakin — Boiler Installations and Steam Generators: Fundamentals and Methodology of Thermal Calculation
The textbook “Boiler Installations and Steam Generators: Fundamentals and Methodology of Thermal Calculation” by Karyakin covers the principles of thermal calculation for steam boilers—a key topic within the academic discipline “Boiler Installations and Steam Generators.” It outlines the methodology for performing verification-based thermal calculations for boilers and analyzing the resulting data, while providing the necessary regulatory standards required for these calculations.
This manual was developed by the Department of Steam Generator Engineering and Steam Generating Installations and is intended for students pursuing a degree in the field of “Thermal Power Engineering and Heat Technology” (code 140100).
“Boiler Installations and Steam Generators” is a specialized course within the “Thermal Power Engineering and Heat Technology” curriculum.
A boiler installation, as a core component of a thermal power plant, consists of a complex array of equipment designed to produce steam, which is then used to drive steam turbines that, in turn, rotate electric generators.
The primary unit within a boiler installation is the steam boiler itself. To support its operation, the installation includes auxiliary equipment; when the boiler runs on solid fuel, this includes fuel preparation systems, draft and forced-air systems, and ash-collection (particulate removal) equipment. If the boiler uses liquid or gaseous fuel, ash-collection systems are not required, as these fuels contain virtually no ash.
Boiler installations at large combined heat and power (CHP) plants typically utilize drum-type steam boilers with natural circulation, operating at medium (10 MPa) or high (14 MPa) pressure, with capacities reaching up to 670 tons per hour. Condensing power plants (CPPs) utilize—as their primary equipment—once-through (subcritical and supercritical, i.e., 25 MPa) steam generators with capacities of 670, 1000, 1650, 2500, and 3650 t/h.
The main components (elements) of a steam boiler include the furnace, superheater, economizer, and air preheater. Boilers with natural circulation feature a steam drum, whereas once-through boilers do not.
The curriculum for the course “Boiler Installations and Steam Generators” requires students to study and personally perform a thermal calculation for a steam boiler.
This textbook provides information on the fundamentals of steam boiler thermal calculations, specifically using the verification (rating) method. It includes the necessary regulatory data for performing these calculations, as well as recommendations for analyzing the resulting data.
The material presented is based on the standard regulatory method for boiler calculations, drawing upon textbooks by I. D. Fursov, V. V. Konovalov, Yu. M. Lipov, and other authors.